Technical specifications
DNS Series (SINGLE PHASE)  | GW3000D-NS  | GW3600D-NS  | GW4200D-NS  | GW5000D-NS  | GW6000D-NS  | 
PV String Input Data  | |||||
Max. DC Input Power (W)  | 3900  | 4680  | 5460  | 6500  | 7200  | 
Max. DC Input Voltage (V)  | 600  | 600  | 600  | 600  | 600  | 
MPPT Range (V)  | 80~550  | 80~550  | 80~550  | 80~550  | 80~550  | 
Start-up Voltage (V)  | 120  | 120  | 120  | 120  | 120  | 
Nominal DC Input Voltage (V)  | 360  | 360  | 360  | 360  | 360  | 
Max. Input Current (A)  | 11/11  | 11/11  | 11/11  | 11/11  | 11/11  | 
Max. Short Current (A)  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | 13.8/13.8  | 
No. of MPP Trackers  | 2  | 2  | 2  | 2  | 2  | 
No. of Input Strings per Tracker  | 1  | 1  | 1  | 1  | 1  | 
AC Output Data  | |||||
Nominal Output Power (W)  | 3000*1  | 3680*1  | 4200*1  | 5000*1  | 6000*1  | 
Max. Output Apparent Power (VA)  | 3000  | 3680  | 3680  | 5000  | 6000  | 
Nominal Output Voltage (V)  | 220/230  | 220/230  | 220/230  | 220/230  | 220/230  | 
Nominal Output Frequency (Hz)  | 50/60  | 50/60  | 50/60  | 50/60  | 50/60  | 
Max. Output Current (A)  | 13.6  | 16  | 19  | 22.8  | 27.3  | 
Max. AC current [A]  | 12  | 14  | 15  | ||
Output Power Factor  | ~1 (Adjustable from 0.8 leading to 0.8 lagging)  | ||||
Output THDi (@Nominal Output)  | <3%  | ||||
Efficiency  | |||||
Max. Efficiency  | 97.8%  | 97.8%  | 97.8%  | 97.8%  | 97.8%  | 
European Efficiency  | 97.5%  | 97.5%  | 97.5%  | 97.5%  | 97.5%  | 
Protection  | |||||
Anti-Islanding Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Input Reverse Polarity Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Insulation Resistor Detection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Residual Current Monitoring Unit  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Output Over Current Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Output Short Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
Output Over Voltage Protection  | Integrated  | Integrated  | Integrated  | Integrated  | Integrated  | 
General Data  | |||||
Operating Temperature Range (°C)  | -25~60  | -25~60  | -25~60  | -25~60  | -25~60  | 
Relative Humidity  | 0~100%  | 0~100%  | 0~100%  | 0~100%  | 0~100%  | 
Operating Altitude (m)  | ≤4000  | ≤4000  | ≤4000  | ≤4000  | ≤4000  | 
Cooling  | Natural Convection  | ||||
Noise (dB)  | <25  | <25  | <25  | <25  | <25  | 
User Interface  | LCD & LED  | LCD & LED  | LCD & LED  | LCD & LED  | LCD & LED  | 
Communication  | RS485 or WiFi or LAN  | ||||
Weight (kg)  | 13  | 13  | 13  | 13  | 13.5  | 
Size (Width*Height*Depth mm)  | 354*433*147  | ||||
Protection Degree  | IP65  | IP65  | IP65  | IP65  | IP65  | 
Night Self Consumption (W)  | <1  | <1  | <1  | <1  | <1  | 
Topology  | Transformerless  | ||||
Certifications & Standards  | |||||
Grid Regulation  | VDE-AR-N 4105, VDE0126-1-1 EN50438(PL), EN50438(SW), AS4777.2, G83, IEC61727, IEC62116, CEI 0-21, RD 1699:2011 , UNE 206006 IN: 2011 , UNE 206007-1 IN: 2013  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL), EN50438(SW),AS4777.2,G59, IEC61727, IEC62116,CEI 0-21, RD 1699:2011, UNE 206006 IN: 2011 ,UNE 206007-1 IN: 2013  | VDE-AR-N 4105, VDE0126-1-1, EN50438(PL), EN50438(SW), AS4777.2, G59, IEC61727, MEA, PEA, IEC62116, CEI 0-21, RD 1699:2011 , UNE 206006 IN: 2011 , UNE 206007-1 IN:2013  | VDE-AR-N 4105, VDE0126- 1-1, EN50438(PL),EN50438(SW), AS4777.2, G59, IEC61727, MEA, PEA, IEC62116, CEI 0-21  | |
Safety Regulation  | IEC62109-1&-2  | ||||
EMC  | EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4, EN61000-4-16, EN61000-4-18, EN61000-4-29  | ||||
*1For CEI 0-21 Nominal Output Power GW3000D-NS is 2700, GW3680D-NS is 3350, GW4200D-NS is 3800, GW5000D-NS is 4540, GW6000D-NS is 5450.
For AS4777, Nominal Output Power GW5000D-NS is 4999.