TECHNICAL SPECIFICATIONS                                                                                                     
                                                             
                                                                                     
Model1KW1.5KW2KW3KW4KW5KW6KW8KW10KW12KW15KW18KW
Continuous Output Power1KW1.5KW2KW3KW4KW5KW6KW8KW10KW12KW15KW18KW
Surge Rating(20s)3KW4.5KW6KW9KW12KW15KW18KW24KW30KW36KW45KW54KW
Inverter Output
Output WaveformPure Sine wave / Same as input(Bypass Mode)
Nominal Efficiency>88% (Peak)
Line Mode Efficiency>95%
Power Factor0.9-1.0
Nominal Output Voltage rms100-110-120Vac / 220-230-240Vac
Output Voltage Regulation±10% RMS
Output Frequency50Hz ± 0.3Hz/60Hz ± 0.3Hz
Short Circuit ProtectionYes( 1 sec after fault)
Typical Transfer Time10ms (Max)
THD< 3% (Rated battery level, rated full linear load)
DC Input
Nominal Input Voltage12V/24V12V/24V/48V24V/48V24V/48V/96V48V/96V
Minimum Start Voltage10.0Vdc / 10.5Vdc for 12Vdc Mode*2 for 24Vdc, *4 for 48Vdc, *8 for 96Vdc 
Low Battery Alarm10.5Vdc / 11.0Vdc for 12Vdc Mode
Low Battery Trip10.0Vdc / 10.5Vdc for 12Vdc Mode
High Voltage Alarm16.0Vdc for 12Vdc Mode
Low Battery voltage recover15.5Vdc for 12Vdc Mode
Idle Consumption-Search Mode< 25 W when Power Saver On.(Refer to Table )
AC Charger
Output VoltageDepends on battery type (Refer to Table 2.5.2)
Charger Breaker Rating20A20A20A25A32A40A40A50A80A80A100A125A
Max Charge Power Rate1/3 Rating Power (Refer to Table 2.5.3)  
Battery Initial Voltage for Start 10-15.7Vdc for 12Vdc Mode*2 for 24Vdc, *4 for 48Vdc, *8 for 96Vdc
Over Charge Protection S.D.15.7Vdc for 12Vdc Mode
Battery Type SelectorSwitching SettingDescriptionFast Mode/ VDCFloat Mode/ VDC
0Charger Off
1Gel USA14.013.7
2AGM 114.113.4
3Lithium13.813.6
4Sealed Lead Acid14.413.6
5Gel EURO14.413.8
6Open Lead AckJ14.813.8
7LifePO414.013.8
8De-sulphation15.5 (4 hours then off)13.8
9Classic LFP13.613.5
For 12Vdc Mode Series (*2 for 24Vdc Mode;*4 for 48Vdc Mode;*8 for 96Vdc Mode)
BTS
Battery Temperature Sensor(Optional) Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature.
Bypass & Protection
Input Voltage WaveformSine wave (Grid or Generator)
Nominal Voltage100-110-120Vac/ 220-230-240Vac
Max Input AC Voltage150Vac For 120Vac LV Mode : 300Vac For 230Vac HV Mode:
Nominal Input Frequency50Hz / 60Hz
Low Freq Trip47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
High Freq Trip55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
Overload Protection (SMPS load)Circuit Breaker
Output Short Circuit ProtectionCircuit Breaker
Bypass Breaker Rating20A20A20A25A32A40A40A50A80A80A100A125A
Transfer Switch Rating30Amp for UL&TUV40Amp for UL80Amp for UL100Amp for UL
Bypass without Battery ConnectedYes (optional)
Max Bypass Current30Amp 40Amp80Amp80Amp
Solar Charger (optional)
Rated Voltage12Vdc24Vdc48Vdc
Rated Charge Current
(Includes Load Current)
40A/60Amp40Amp
Load Current15Amp
Input Voltage Range15-150Vdc30-150Vdc60-150Vdc
Max. PV Open Circuit Array Voltage150Vdc
Overload Protection (DC Load)2.0*I (Rated) >5s; 1.5*I (Rated) >20s;  1.25*I (Rated)  Temperature Controlled
Typical Idle ConsumptionAt idle < 10mA
Bulk Charge14.6Vdc29.2Vdc58.4Vdc
Floating Charge13.4Vdc26.8Vdc53.6Vdc
Equalization Charge14.0Vdc28.9Vdc58.0Vdc
Over Charge Disconnect14.8Vdc29.6Vdc59.2Vdc
Over Charge Recovery13.6Vdc27.2Vdc54.4Vdc
Over Discharge Disconnect10.8Vdc21.6Vdc43.2Vdc
Over Discharge Reconnect12.4Vdc24.6Vdc49.6Vdc
Temperature Compersation- 13.2mV/ºC- 26.4mV/ºC- 52.8mV/ºC
Lead Acid Battery SettingsAdjustable
NiCad Battery SettingsAdjustable
Low Voltage Reconnect12.0 - 14.0Vdc24.0 - 28.0Vdc48.0 - 56.0Vdc
Low Voltage Disconnect10.5 - 12.5Vdc21.0 - 25.0Vdc42.0 - 50.0Vdc
Ambient Temperature0-40ºC (Full load)  40-60ºC (De-rating)
Weight (KG)2.5
Mechanical Specifications 
MountingWall Mount
DisplayStatus LEDs / Status LEDs+LCD
Inverter Dimensions(L*W*H) mm 388*415*200488*415*200588*415*200688*415*230
Packing Dimensions(L*W*H) mm 550*520*310650*520*310750*520*310850*520*350
N.W. (KGS)212223273848496066707578
G.W. (KGS)242526304151526369737881
                                                                                







CERTIFICATIONS                                                                                                                         

LCD Display off Grid DC AC Solar Panel Hybrid Inverter 10kw 48V 96V










PROJECTS REFERENCE                                                                                                               

LCD Display off Grid DC AC Solar Panel Hybrid Inverter 10kw 48V 96V











FACTORY SHOW                                                                                                                           
LCD Display off Grid DC AC Solar Panel Hybrid Inverter 10kw 48V 96V




 
     


FAQ                                                                                                                                               


Q1: How about your delivery time?
A   : If there are in stock, we will arrange the shipping within two working days after payment arrived in our account. 
If without any stocking, the specific producing time depends on the items and the quantity of your order, frequencyly be 10-25 workdays.


Q2: What is your sample policy?
A   : We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.

Q3: Does SOPOWER's inverters could power all kinds of loads?
A   : Generally speaking, there are two kinds of load appliances, resistive load appliances and inductive load appliances. 
Appliances like mobile phones, computers, LCD TVs, incandescents, electric fans, video broadcast,  small printers, electric mahjong machines, rice cookers etc. All belong to resistive loads. Modified sine wave inverters and pure sine wave inverters can drive them successfully.
Inductive load appliances refer to the application of electromagnetic induction's principle, produced by high-power electrical products, such as motor type, compressors, relays, fluorescent lamps, electric stove, refrigerator, air conditioner, energy saving lamps, pumps, etc. These products' power are far more than the rated power (about 3-7 times) when start. So only pure sine wave inverter is available to them.
All of our inverters are pure sine wave, could work with them smoonthly.


Q4: What should be noticed when installing inverter?
A   : Put the product in a place where is well ventilate,cool, dry and water-proof. Pls do not stress and do not put foreign objects into the inverter.Rember to turn on the inverter before turn on the appliance.

Q5: How do you make our business long-term and good relationship?
A   : 1. We keep good quality and competitive price to ensure our customers' benefit;
    2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours