1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter

1KW 2KW 3KW 4KW 5KW 6KW 7KW 8KW power inverter off grid solar inverter hybrid inverter Different Features High frequency MPPT solar inverter solar hybrid inverter(Based on IGBT)1. HD plus 1000va 2000va modified sine wave inverter with PWM 40A solar charge controller2. PSC plus 3000va 5000va pur

Featured Products

1KW 2KW 3KW 4KW 5KW 6KW 7KW 8KW power inverter off grid solar inverter hybrid inverter

 

Different Features

 

High frequency MPPT solar inverter solar hybrid inverter(Based on IGBT)

1. HD plus 1000va 2000va modified sine wave inverter with PWM 40A solar charge controller
2. PSC plus 3000va 5000va pure sine wave inverter with MPPT 40A,60A solar charge controller
3. Auto restart when AC recovers


Low frequency MPPT solar inverter solar hybrid inverter(Based on Transformer)
1. GS 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can show solar and inverter parameters
2. GW Plus 1-12KW pure sine wave inverter with MPPT solar charge controller, LCD can only show inverter parameters
3. Generator restart signal
4. 3 times peak power

 

 

Same Features

1. Compatible to mains or generator power
2. AC and solar charger
3. Wide dc input votlage 80-270vac
4. Compatible to mains or generator power
5. Selectable AC or solar priority function6. Adjustable charging current





Application

ZLPOWER 1-12kw power inverter off grid solar inverter hybrid inverter can work with solar energy, generator and AC mains. They are widely used for home appliances and office devices for long time backup. 



Specifications


GS 1-12kw

MODEL
(GS Series)
HV/LV Model
HV Model(4-10KW)  LV Model(4-6KW)

Line Mode Specifications:

Input VoltageInput Voltage WaveformSinusoidal (utility or generator)
Nominal Input VoltageLV 120VacHV 230Vac
Low Line DisconnectNormal:85Vac±4% Wide:80Vac±4%Normal:184Vac±4% Wide:135Vac±4%
Low Line Re-connectNormal:95Vac±4% Wide:85Vac±4%Normal:194Vac±4% Wide:145Vac±4%
High Line DisconnectNormal:136Vac±4% Wide:140Vac±4%Normal:263Vac±4% Wide:263Vac±4%
High Line Re-connectNormal:131Vac±4% Wide:135Vac±4%Normal:253Vac±4% Wide:253Vac±4%
Max AC Input Voltage150Vrms270Vrms
Input FrequencyNominal Input Frequency50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
Low Line Frequency Disconnect50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
High Line Frequency Re-connect64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
High Line Frequency Disconnect65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
main functionsOutput Voltage WaveformAs same as Input Waveform
Over-Load Protection (SMPS load)Air switch
Output Short Circuit ProtectionAir switch
Max Bypass Overload Current40A/50A/80A

Battery Invert Mode Specifications:

AC outputOutput Voltage WaveformSine wave
Rated Output Power (KW)LV:4KW/5KW/6KWHV: 4KW/5KW/
6KW/7KW/8KW/10KW
Power Factor0.9~1.0
Nominal Output Voltage (V)LV:120Vac ±10%rmsHV:230Vac ±10%rms
Nominal Output Frequency (Hz)60Hz ± 0.3Hz
50Hz ± 0.3Hz
DC VoltageNominal DC Input Voltage24VDC/48VDC
DC Voltage range20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
Low Battery Alarm21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
Low DC input Shut-down20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
High DC input Alarm & Fault32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
High DC input Recovery31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
AC ChargerNominal Charge Current35A/50A/70A (5 stages adjustable charging current)
Charge Current Regulation± 5Adc
Over Charge ProtectionBat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
AlgorithmThree stage:  Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Solar chargerRated Charge Current40A60A
Rated charge battery Voltage type24V/48V24V
Max.PV open circuit array voltage24V for 55Vdc
48V for 110Vdc
Charger modeMPPT
PV Low Voltage Re-connectPV≥Bat.V=3V
PV Low Voltage DisconnectPV<=Bat.V
Efficiency≥97%
EfficiencyEfficiency (Battery Mode)≥85%
Efficiency (Line Mode)>98%
Transfer TimeAc to Dc20ms (Max)
Dc to Ac15ms (Max)
System parameterOver-Load Protection110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Surge rating (10s)1:3 (VA)
Power saverLoad <=25W (Enabled on "P/S auto" setting of Remote control)
ProtectionsLow battery, over charging, over load , over temp.
IndicatorsLED+LCD Display
General SpecificationsOperating Temperature Range0°C to 40°C
Storage temperature-15ºC ~60ºC
Operation humidity5% to 95%(non-condensing)
Audible Noise60dB max
CoolingForced air, variable speed fan
Dimension(L*W*H)4KW5KW6KW7KW8KW10KW
530*400*190mm590*420*195mm
Net weight(Kg)30.035.538.541.548.055.0


GW Plus
MODEL
(GW Series)
HV/LV Model
HV Model(1-12KW)  LV Model(1-6KW)

Line Mode Specifications:

Input VoltageInput Voltage WaveformSinusoidal (utility or generator)
Nominal Input VoltageLV 120VacHV 230Vac
Low Line DisconnectNormal:85Vac±4% Wide:80Vac±4%Normal:184Vac±4% Wide:135Vac±4%
Low Line Re-connectNormal:95Vac±4% Wide:85Vac±4%Normal:194Vac±4% Wide:145Vac±4%
High Line DisconnectNormal:136Vac±4% Wide:140Vac±4%Normal:263Vac±4% Wide:263Vac±4%
High Line Re-connectNormal:131Vac±4% Wide:135Vac±4%Normal:253Vac±4% Wide:253Vac±4%
Max AC Input Voltage150Vrms270Vrms
Input FrequencyNominal Input Frequency50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
Low Line Frequency Disconnect50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
High Line Frequency Re-connect64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
High Line Frequency Disconnect65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
main functionsOutput Voltage WaveformAs same as Input Waveform
Over-Load Protection (SMPS load)Air switch
Output Short Circuit ProtectionAir switch
Max Bypass Overload Current30A/40A/50A

Battery Invert Mode Specifications:

outputOutput Voltage WaveformSine wave
Rated Output Power (KW)LV:1~6KW     HV: 1~12KW
Power Factor0.9~1.0
Nominal Output Voltage (V)LV:120Vac ±10%rmsHV:230Vac ±10%rms
Nominal Output Frequency (Hz)60Hz ± 0.3Hz
50Hz ± 0.3Hz
DC VoltageNominal DC Input Voltage12VDC/24VDC/48VDC
DC Voltage range10-15.5Vdc for 12VDC
20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
Low Battery Alarm10.5Vdc ± 0.3Vdc for 12V battery
21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
Low DC input Shut-down10.0Vdc ± 0.3Vdc for 12V battery
20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
High DC input Alarm & Fault16Vdc ± 0.3Vdc for 12V battery
32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
High DC input Recovery15.5Vdc ± 0.3Vdc for 12V battery
31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
AC ChargerNominal Charge Current20A/35A/50A/70A/90A(5 stages adjustable charging current)
Charge Current Regulation± 5Adc
Over Charge ProtectionBat.V≥15.5VDC for 12V battery
Bat.V≥31.0VDC for 24V battery
Bat.V≥62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
AlgorithmThree stage:  Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Solar chargerRated Charge Current40A60A
Rated charge battery Voltage type12V/24V/48V12V/24V
Max.PV open circuit array voltage12V for 40Vdc
 24V for 55Vdc
48V for 110Vdc
Charger modeMPPT
PV Low Voltage Re-connectPV≥Bat.V=3V
PV Low Voltage DisconnectPV<=Bat.V
Efficiency≥97%
EfficiencyEfficiency (Battery Mode)≥85%
Efficiency (Line Mode)>98%
Transfer TimeAc to Dc20ms (Max)
Dc to Ac15ms (Max)
System parameterOver-Load Protection110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Surge rating (10s)1:3 (VA)
Power saverLoad <=25W (Enabled on "P/S auto" setting of Remote control)
ProtectionsLow battery, over charging, over load , over temp.
IndicatorsLED+LCD Display
General SpecificationsOperating Temperature Range0°C to 40°C
Storage temperature-15ºC ~60ºC
Operation humidity5% to 95%(non-condensing)
Audible Noise60dB max
CoolingForced air, variable speed fan
Dimension(L*W*H)3KW5KW6KW8KW10KW12KW
   
Net weight(Kg)      



PSC Plus
Parameters            ModelPSC Plus3K-24PSC Plus5K-48
AC
Input
Nominal Power3KVA/2400W5KVA/4200W
Input Voltage WaveformSinusoidal (utility or generator)
Nominal input Voltage230VAC
Low Line  Disconnect170Vac±4%(Normal) or 90Vac±4%(Wide & Generator)175Vac±4%(Normal) or
125Vac±4%(Wide & Generator)
Low Line  Re-connect180Vac±4%(Normal) or 100Vac±4%(Wide & Generator)185Vac±4%(Normal) or 135Vac±4%(Wide & Generator)
High Line  Disconnect280Vac±4%(Normal) or 280Vac±4%(Wide & Generator)280Vac±4%(Normal) or 280Vac±4%(Wide & Generator)
High Line Re-connect275Vac±4%(Normal) or 275Vac±4%(Wide & Generator)275Vac±4%(Normal) or 275Vac±4%(Wide & Generator)
Max AC input VoltageMax:300VAC
Frequency50Hz/60Hz(Auto detection)
AC
output
Output Voltage WaveformSine wave
Power Factor0.80.84
Nominal Output
Frequency (Hz)
50Hz / 60Hz ± 1Hz
Capable of starting electric motor1.5HP2.5HP
Full load efficiency≥90%
Solar
charger
Charger  modeMPPT
Rated Charge Current40A60A
Max PV input Voltage75VDC150VDC
AC
Charger
Nominal Charger Current20A @170Vac~280Vac; 10A @90Vac~170Vac25A @180Vac~280Vac; 20A @125Vac~180Vac
Over charge Protection30VDC60VDC
Floating Charge Voltage27.4VDC54.8VDC
Battery
Voltage
Nominal DC input Voltage24VDC48VDC
Low Battery Alarm21VDC42VDC
High DC input Alarm & Fault29VDC58VDC
 Transfer TimeNormal range : 10ms (typical) 15ms (max)
Generator/wide range: 20ms (typical) 40ms (max)
System
Parameter
Over-Load Protection110%<load<150%,beeps 0.5s every 1s,and Fault after 10s off
the output,load≥150%,beeps 0.5s every 1s,and Fault after 5s
 Output Short Circuit ProtectionCurrent limit (Fault after 4 cycles max)
 Surge Rating1:2(VA)
 ProtectionsLow battery, over charging, over load, over temp
General
Specifications
Operating Temperature Range0ºC to 40ºC
Storage Temperature-15ºC~60ºC
Operation Humidity5% to 95%(non-condensing)
Audible Noise60dB max
coolingForced  air, variable speed fan
Dimension(L*W*H)326*268*88.8mm456*356.8*118mm
Net Weight(kg)5.6kg11.1kg
 
 

HD Plus
Parameters                  ModelHD Plus1K-12HD Plus2K-24
AC
Input
Nominal Power1KVA/720W2KVA/1300W
Input Voltage WaveformNominal input Voltage
Nominal input Voltage230VAC
Selectable Voltage Range165-270Vac±4%(Narrow Range)                                                                                                                                                                         85-270Vac±4%(Wide Range)
Max AC input VoltageMax:270VAC
Frequency50Hz:or 60Hz
AC
output
Output Voltage WaveformModified sine wave
Voltage Regulation                (Bat. Mode)230VAC (+10% / -18%)
Nominal Output
Frequency (Hz)
50Hz or 60Hz (Auto detection)
Transfer Time15ms Typical, 20ms Max.
Solar
charger
Charger  modePWM
Maximum PV Array Power450W900W
Optimal Work Voltage Rang15VDC-18VDC30VDC - 36VDC
MAX. PV input Voltage55VDC
MAX. PV input Current40Amp
AC
Charger
Charging Algorithm3-step charging
Nominal Charger Current15 Amp or 20Amp Selectable10Amp
Floating Charging Voltage13.7VDC27.4VDC
Over charge Protection16VDC32VDC
EfficiencyEfficiency                  (Battery Mode)>80%
Efficiency                                (Line Mode)>95%
Battery
Voltage
Nominal DC input Voltage12VDC24VDC
Low Battery Alarm10.5VDC±0.3VDC21VDC±0.6VDC
Low DC input shut-down10VDC±0.3VDC20VDC±0.6VDC
High DC input
Alarm & Fault
16VDC±0.3VDC32VDC±0.6VDC
System
Parameter
ProtectionsLow battery, over charging, over load, over temp
IndicatorsLCD+LED Display
Over-Load Protection1min Load >110%,20s Load >120%,0s Load >150%
General
Specifications
Operating Temperature
Range
0ºC to 40ºC
Storage Temperature-15ºC~55ºC
coolingForced air, variable speed fan
Dimension(L*W*H)276.7*245*97mm
Net Weight(kg)2.62.7




Photos


1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter
1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter1kw 2kw 3kw 4kw 5kw 6kw 7kw 8kw Power Inverter off Grid Solar Inverter Hybrid Inverter




Why Choose Us

1, the company professional to do Inverter, Battery and UPS
2, the quality of ZLPOWER Products are in the top level
3, stable product quality , supply, the good faith management

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours