solar inverter low frequency 220v 60hz inverter single phase inverter
1. GW Plus Series AC/Solar charging hybrid off grid inverter.
2. LED/LCD display, Enhanced functions setting via LCD.Man-machine intelligent design.
3. Built-in 40A/60A optional MPPT solar charger controller.
4. Remote external display panel realize remote operation.
5. 5 stages adjustable AC charging current. AC charging also can be closed.
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact).
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection.


Shipping:company standard
Delivery: sea transaction, air parcel, international express service(FEDEX, DHL, TNT, UPS, Shunfeng Exprress, and so on).
Our company


1. GW Plus Series AC/Solar charging hybrid off grid inverter.
2. LED/LCD display, Enhanced functions setting via LCD.Man-machine intelligent design.
3. Built-in 40A/60A optional MPPT solar charger controller.
4. Remote external display panel realize remote operation.
5. 5 stages adjustable AC charging current. AC charging also can be closed.
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact).
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection.


| Model | GW Plus1KW | |
| AC Input | Nominal Power | 1000W |
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal input Voltage | 120/230VAC | |
| Low Line Disconnect | 85Vac±4%(Normal) or 80Vac±4% (Wide) for 120V 184Vac±4%(Normal) or 135Vac±4%(Wide) for 230V | |
| Low Line Re-connect | 95Vac±4%(Normal) or 85Vac±4% (Wide) for 120V 194Vac±4%(Normal) or 145Vac±4%(Wide) for 230V | |
| High Line Disconnect | 136Vac±4%(Normal) or 140Vac±4%(Wide) for 120V 263Vac±4%(Normal) or 263Vac±4%(Wide) for 230V | |
| High Line Re-connect | 131Vac±4%(Normal) or 135Vac±4% (Wide) for 120V 253Vac±4%(Normal) or 253Vac±4%(Wide) for 230V | |
| Max AC input Voltage | 120V for Max150V / 230V for Max270V | |
| Frequency | 50Hz:41-54Hz / 60Hz:51-64Hz | |
| AC output | Output Voltage Waveform | Sine wave |
| Power Factor | 0.9~1.0 | |
| Nominal Output Voltage (V) | LV:120Vac ±10%rms / HV:230Vac ±10%rms | |
| Nominal Output | 50Hz ± 0.3Hz / 60Hz ± 0.3Hz | |
| Frequency (Hz) | ||
| Transfer Time | 20ms(max) | |
| Solar charger | Rated Charge Current | 40A |
| PV Input Voltage range | 30VDC-55VDC for 24VDC / 60-110VDC for 48V | |
| Max. PV open circuit array voltage | 12V for 40Vdc,24V for 55Vdc,48V for 110Vdc | |
| Charger mode | MPPT | |
| Efficiency | ≥97% | |
| AC Charger | Nominal Charger Current | 35A/50A/70A/90A(According to the inverter model) 5 stages adjustable charging current |
| Over charge Protection | Bat.V≥15.5VDC for 12V battery,Bat.V≥31.0VDC for 24V battery,Bat.V≥62.0VDC for 48V battery ,beeps 0.5s every 1s & fault after 60s | |
| Efficiency | Efficiency(Battery Mode) | ≥87% |
| Efficiency (Line Mode) | >98% | |
| Battery Voltage | Nominal DC input Voltage | 12/24/48VDC |
| Low Battery Alarm | 10.5VDC±0.3VDC for 12VDC | |
| 21VDC±0.6VDC for 24VDC | ||
| 42VDC±1.2VDC for 48VDC | ||
| High DC input Alarm & Fault | 16VDC±0.3VDC for 12VDC | |
| 32VDC±0.6VDC for 24VDC | ||
| 64VDC±1.2VDC for 48VDC | ||
| System Parameter | Over-Load Protection | 110%150%,beeps 0.5s every 1s,and Fault after 20s |
| Output Short Circuit Protection | Current limit (Fault after 10s) | |
| Surge Rating(10s) | 1:3(VA) | |
| Protections | Low battery, over charging, over load, over temp | |
| General Specifications | Storage Temperature | -15ºC~60ºC |
| Audible Noise | 60dB max | |
| cooling | Forced air , variable speed fan | |
| Dimension(L*W*H) | 480*336*190mm | |
| Net Weight(kg) | 22.5 | |
Shipping:company standard
Delivery: sea transaction, air parcel, international express service(FEDEX, DHL, TNT, UPS, Shunfeng Exprress, and so on).
Our company

